Data cables for electronics and a computer technique

Technical data:

Temperature rangein motion -5°C till +50°C
fixed-30°C till +70°C
Bending radiusin motionx diameter10
FlammabilitystandardEN 60332-1-2
Insulation resistancemin.[MOhm/km]100

Application:

To be installed in dry and humid rooms and used as a termination and connection cable in the control, measuring and signal technology.

Technical data:

Temperature rangein motion -5°C till +50°C
one time / fixed-30°C till +70°C
Bending radiusin motionx diameter10
FlammabilitystandardEN 60332-1-2
Insulation resistancemin.[MOhm/km]100

Application:

To be installed in dry and humid rooms and used as a termination and connection cable in the control, measuring and signal technology.

Technical data:

Temperature rangein motion -5°C till +50°C
one time / fixed-30°C till +70°C
Bending radiusin motionx diameter10
FlammabilitystandardEN 60332-1-2
Insulation resistancemin.[MOhm/km]100
Mutal capacitancemax.[nF/km]120

Application:

To be installed in dry and humid rooms and used as a termination and connection cable in the control, measuring and signal technology.

Technical data:

Operating peak voltage[V]225 volt
Test voltage at 50 Hzcore / core[V]AC500
core / screen[V]AC2000
Temperature rangein motion -5°C till +50°C
one time / fixed-30°C till +70°C
Bending radiusin motion x diameter15
FlammabilitystandardEN 60332-1-2
Insulation resistancemin.[MOhm/km]100
Mutal capacitance[Ohm/km]73,2
Mutal capacitancemax.[nF/km]100
Capacitance unbalance 100mmax.[pF]200

Application:

Cables for industrial electronics are suitable for fixed Installations in dry and humid rooms.

Technical data:

Operating peak voltage Uo/U[V]225
Test voltage at 50 Hzcore / core[V]AC500
core / screen[V]AC2000
Temperature rangein motion -5°C till +50°C
one time / fixed-30°C till +70°C
Bending radiusin motion x diameter10
FlammabilitystandardEN 60332-1-2
Insulation resistancemin.[MOhm/km]100
Mutal capacitance[Ohm/km]78,4
max.[nF/km]100
Capacitance unbalance 100mmax.[pF]200

Application:

Cables for industrial electronics are suitable for fixed Installations in dry and humid rooms.

Technical data:

Operating peak voltage Uo/U[V]350
Test voltage[V]AC800
Temperature rangein motion+5°C till +50°C
FlammabilitystandardEN 60332-1-2
Conductor resistancemax.[Ohm/km]26
Mutal capacitancemax.[nF/km]130

Application:

To be installed in dry and humid rooms as termination and connection cable in the low-frequency and studio technology.

Technical data:

Temperature rangein motion-5°C till +70°C
Insulation resistanceR iso[MOhm/km]5000
Mutal capacitance[Ohm/km]39
Attenuation100 MHz[dB / 100 m]4,5
Impedance1 KHz[Ohm]465
Impedance10 KHz[Ohm]155
Impedance100 KHz[Ohm]115
Cross-talk attenuationat 60 Hz[dB/500 m]78

Application:

These transmission cables are to be installed in dry and humid rooms. They are used in data processing and process controlling for high-speed transmission.

Technical data:

Nominal voltage Uo/U[V]125 volt
Temperature rangein motion0°C till +50°C
Conductor resistancemax.[Ohm/km]110
Insulation resistancemin.[GOhm/km]5
Mutal capacitancenom.[nF] max.29
Capacitance unbalancemax.[nF] max.1
Bending radiusmin.v [mm]75

Application:

Suitable for applications indoors on the wall or in the floor as well as in cable ducts as a data transmission cable for IBM-LAN systems and EC-aprroved "non plenum type".

Technical data:

Operating peak voltage Uo/U[V]300
Temperature rangein motion -5°C till +50°C
one time / fixed-30°C till +70°C
Conductor resistancemax.[Ohm/km]73,2
Insulation resistancemin.[MOhm/km]100
Mutal capacitanceat 800 Hz[nF] max.100
Test voltagecore / core[KV] 5 min.1
Core and Screen on
Conductorsurface[KV] 1 min.4
Bending radiusx diameter15

Application:

The installation in, on and under the wall surface, in dry, humid and wet locations as well as outdoors (if protected) is admissible. As BUS-installation cable (EIB-installation bus) it may be used in HV and LV installations, as control and instrumentation cable (MSR-cable) in HV installations. Suitable for the transmission of measuring data, for the installation in the processing and for the application in the field of the control technology.

Technical data:

Operating peak voltage Uo/U[V]300
Temperature rangein motion -5°C till +50°C
one time / fixed-30°C till +70°C
Conductor resistancemax.[Ohm/km]130
Insulation resistancemin.[GOhm/km]5
Impendance1-100 MHz[Ohm]+-15%100
Mutal capacitancenom.[nF] max.52
Wave damping1,0 MHz[dB/100 m]35
4,0 MHz[dB/100 m]55
10,0 MHz[dB/100 m]73
16,0 MHz[dB/100 m]86
Cross-talk attenuation1,0 MHz[dB]30
10,0 MHz[dB]30

Application:

This Integrated Services Digital Network (ISDN) cable is to be used as a termination and connection cable for the transmission of analogue to digital signals up to 16 MHz. It is suitable for ISDN applications in this frequency range such as BTX or fax. Peculiarities of this cable are the cores which are stranded to star quads.

Technical data:

Temperature rangein motion-40°C till +70°C
Conductor resistancemax.[Ohm/km]57,1
Insulation resistancemin.[MOhm/km]1000
Impendance1,0-5,0 MHz[Ohm]150
Bending radiusmin.[mm]150
For other types and standards please send us an inquiry.

Application:

As an access and connection lines circuit in mechanical engineering, e.g., as a connection circuit between bus segments. By the special construction the circuit is suitable for the application with quick connection technology

Technical data:

Temperature rangein motion-5°C till +60°C
one time / fixed 0°C till +50°C
Conductor resistancemax.[Ohm/km]83
Impendance1-100 MHz[Ohm]+-15%100
Mutal capacitancenom.[nF] max.50
Attenuation1,0 MHz[dB/100 m]2,7
4,0 MHz[dB/100 m]5,2
10,0 MHz[dB/100 m]8,4
16,0 MHz[dB/100 m]11,2

Application:

The circuit can connect different components within automation devices. The twisted cores are also the basic element. Because all bus components are connected about that, costly parallel wiring can be avoided.

Technical data:

Temperature rangein motion0°C till +50°C
Conductor resistancemax.[Ohm/km]39
Attenuation1-100 MHz[Ohm]+-15%150
Mutal capacitancenom.[nF] max.40

Application:

C(ontroller)A(rea)N(etwork) serves as a system circuit in the industrial range. Professional bus, CAN bus as well as devices LON can be connected with this system solution.

Technical data:

Temperature rangemoved0°C till +60°C
Loop impedance[Ohm/100 m]39
Capacitymax.[nF/km]50
Nom. Velocity of propagationNVP nom.77
Attenuation1-100 MHz[Ohm]100,0 +/- 15
Capacity coupling (f=800 Hz)K<100[pF/100 m]150
Insulation resistance[GOhm/km]5
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø

Application:

In the device connection wiring as a patch, switching, or connecting lead for the use in switching cabinets as well as for the connection of data terminals. Area of application: IEEE 802.3:10 Base T, 10 Base T Ethernet, 100 Base T, 1000 Base T, FDDI, ISDA, AT

Technical data:

Temperature rangemoved0°C till +60°C
Loop impedance[Ohm/100 m]19
Capacitymax.[nF/km]50
Nom. Velocity of propagationNVP nom.77
Attenuation1-100 MHz[Ohm]100
Capacity coupling (f=800 Hz)K<100[pF/100m]150
Insulation resistance[GOhm/km]5
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø

Application:

In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: IEEE 802.3:10 Base T, 10 Base T Ethernet, 100 Base T, 1000 Base T, FDDI, ISDA, ATM

Technical data:

Temperature rangemoved0°C till +60°C
Loop impedance[Ohm/100 m]19
Capacitymax.[nF/km]50
Nom. Velocity of propagationNVP nom.71
Attenuation1-100 MHz[Ohm]100,0 +/- 15
Coupling resistance1-100 MHz[mOhm/m]10
Capacity coupling (f=800 Hz)K<100[pF/100 m]15
Insulation resistance[GOhm/km]>5
Test voltage at 50 Hz[VAC]1000
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø

Application:

In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: IEEE 802.3:10 Base T, 10 Base T Ethernet, 100 Base T, 1000 Base T, FDDI, ISDA, ATM

Technical data:

Temperature rangemoved0°C till +60°C
Loop impedance[Ohm/100 m]19
Capacitymax.[nF/100m]50
Nom. Velocity of propagationNVP nom.77
Impendance1-100 MHz[Ohm]100,0 +/- 15
Coupling resistance1-100 MHz[mOhm/m]10
Capacity coupling (f=800 Hz)K<100[pF/100 m]15
Insulation resistance[GOhm/km]>5
Test voltage at 50 Hz[VAC]700
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø

Application:

In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: IEEE 802.3:10 Base T, 10 Base T Ethernet, 100 Base T, 1000 Base T, FDDI, ISDA, ATM

Technical data:

Temperature rangemoved0°C till +60°C
Loop impedance[Ohm/100 m]19
Capacitymax.[nF/km]50
Nom. Velocity of propagationNVP nom.77
Attenuation1-100 MHz[Ohm]150,0 +/- 22
Coupling resistance1-100 MHz[mOhm/m]10
Capacity coupling (f=800 Hz)K<100[pF/100 m]150
Insulation resistance[GOhm/m]>5
Test voltage at 50 Hz[VAC]700
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø

Application:

In the horizontal cabling as an installation for laying cable in cable channels and pipes inside of telecommunications equipment and data systems to 350 Mhz. Installation is very easy because of a central element (cross) no individual shield is required. Usable for: 10Base-T, 100 Base-T, 1000 Base-T, CDDI/TPDDI, ISDN, ATM 155 Mbit/s, TP-PMD 125 Mbit/s, Token Ring 4/16 Mbit/s.

Technical data:

Temperature rangemoved0°C till +60°C
Loop impedance[Ohm/100 m]14,5
Capacitymax.[nF/km]50
Nom. Velocity of propagationNVP nom.77
Attenuation1-100 MHz[Ohm]100,0 +/- 25
Coupling resistance1-100 MHz[mOhm/m]<10
Capacity coupling (f=800 Hz)K<100[pF/100 m]1500
Insulation resistance[GOhm/m]>5
Test voltage at 50 Hz[VAC]700
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø

Application:

This installation cable is suitable for horizontal laying in cable ducts and conduits in telecommunications and data transmission systems. Useable for: ISDN , B-ISDN, IEEE 802.3 10 Base T Ethernet, IEEE 802.3 100 Base T Ethernet,IEEE 802.5 Token Ring, CDDI (FDDI on Cu), Gigabit-Ethernet , ATM, DQDB, Video.

Technical data:

Temperature rangemoved0°C till +60°C
Loop impedance[Ohm/100 m]14,5
Capacitymax.[nF/km]50
Nom. Velocity of propagationNVP nom.77
Attenuation1-100 MHz[Ohm]100,0 +/- 25
Coupling resistance1-100 MHz[mOhm/m]10
Capacity coupling (f=800 Hz)K<100[pF/100 m]150
Insulation resistance[GOhm/m]>5
Test voltage at 50 Hz[VAC]700
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø

Application:

In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: ISDA, B-ISDA, IEEE 802.3 10 Base T Ethernet, IEEE 802.3 100 Base T Ethernet, IEEE 802.5 Token Ring CCDI (FDDI at Cu), Gigabit-Ethernet, ATM, DQDB, Video

Technical data:

Temperature rangemoved-20°C till +60°C
Loop impedance[Ohm/100 m]11,5
Capacitymax.[nF/km]50
Nom. Velocity of propagationNVP nom.77
Attenuation1-100 MHz[Ohm]100,0 +/- 25
Coupling resistance1-100 MHz[mOhm/m]10
Capacity coupling (f=800 Hz)K<100[pF/100 m]150
Insulation resistance[GOhm/m]>5
Test voltage at 50 Hz[VAC]700
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø

Application:

In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: ISDA, B-ISDA, IEEE 802.3 10 Base T Ethernet, IEEE 802.3 100 Base T Ethernet, IEEE 802.5 Token Ring CCDI (FDDI at Cu), Gigabit-Ethernet, ATM, DQDB, Video

Technical data:

Temperature rangetransport / storage-30°C till +70°C
operational-20°C till +60°C
Bending radiusunder tensionx diameter20
no tensionx diameter15
Further types in singlemode or multimode style upon request

Application:

This metal-free optical fibre outdoor cable is suitable for installations directly into the earth or in conduits in telecommunications and data processing systems. The stranded design (n x m) is available till 60 fibres, and with a multifunctional used reinforced glass roving braiding as a non-metallic stress relieving element and an armour for rodent protection.

Technical data:

Temperature rangetransport / storage-30°C till +70°C
operational-20°C till +60°C
Bending radiusunder tensionx diameter20
no tensionx diameter15
Further types in singlemode or multimode style upon request

Application:

This metal-free optical fibre outdoor cable is suitable for installations directly into the earth or in conduits in telecommunications and data processing systems. The stranded design (n x m) is available till 60 fibres, and with a multifunctional used reinforced glass roving braiding as a non-metallic stress relieving element and an armour for rodent protection.

Technical data:

Temperature rangein motion -5°C till +70°C
fixed-25°C till +60°C
FlammabilitystandardEN 60332-1-2
Further cross-sections and core-quantities as well as standards and configurations upon request

Application:

These cables are suitable for installations in dry, humid and wet locations as temperature measuring cables for areas such as the plastic industry in machine engineering, industrial oven construction as well as blast furnace plants in the steel industry. PVC-, fibre-glass- and asbestos-substitute insulated or sheathed compensating and extension cables are not suitable for open-air use except for the PVC-sheathed solid conductor type which can be used for underground laying, too.

Technical data:

Temperature rangein motion -5°C till +70°C
fixed-25°C till +70°C
FlammabilitystandardEN 60332-1-2
Further cross-sections and core-quantities as well as standards and configurations upon request

Application:

These cables are suitable for installations in dry, humid and wet locations as temperature measuring cables for areas such as the plastic industry in machine engineering, industrial oven construction as well as blast furnace plants in the steel industry. PVC-, fibre-glass- and asbestos-substitute insulated or sheathed compensating and extension cables are not suitable for open-air use except for the PVC-sheathed solid conductor type which can be used for underground laying, too.

Technical data:

Temperature rangein motion-25°C till +180°C
fixed-25°C till +180°C
temporary resilient250°C
FlammabilitystandardEN 60332-1-2
Further cross-sections and core-quantities as well as standards and configurations upon request

Application:

These cables are suitable for installations in dry, humid and wet locations as temperature measuring cables for areas such as the plastic industry in machine engineering, industrial oven construction as well as blast furnace plants in the steel industry. PVC-, fibre-glass- and asbestos-substitute insulated or sheathed compensating and extension cables are not suitable for open-air use except for the PVC-sheathed solid conductor type which can be used for underground laying, too.

Technical data:

Temperature rangein motion-25°C till +180°C
fixed-25°C till +180°C
temporary resilient250°C
FlammabilitystandardEN 60332-1-2
Further cross-sections and core-quantities as well as standards and configurations upon request

Application:

These cables are suitable for installations in dry, humid and wet locations as temperature measuring cables for areas such as the plastic industry in machine engineering, industrial oven construction as well as blast furnace plants in the steel industry. PVC-, fibre-glass- and asbestos-substitute insulated or sheathed compensating and extension cables are not suitable for open-air use except for the PVC-sheathed solid conductor type which can be used for underground laying, too.

This website uses cookies to provide services, personalize ads, and analyzing visitor. By using this site you agree. More informations