Data cables for electronics and a computer technique
Technical data:
Temperature range | in motion | -5°C till +50°C | |
fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 10 |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 100 |
Application:
To be installed in dry and humid rooms and used as a termination and connection cable in the control, measuring and signal technology.
Technical data:
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 10 |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 100 |
Application:
To be installed in dry and humid rooms and used as a termination and connection cable in the control, measuring and signal technology.
Technical data:
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 10 |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | max. | [nF/km] | 120 |
Application:
To be installed in dry and humid rooms and used as a termination and connection cable in the control, measuring and signal technology.
Technical data:
Operating peak voltage | [V] | 225 volt | |
Test voltage at 50 Hz | core / core | [V]AC | 500 |
core / screen | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 15 |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | [Ohm/km] | 73,2 | |
Mutal capacitance | max. | [nF/km] | 100 |
Capacitance unbalance 100m | max. | [pF] | 200 |
Application:
Cables for industrial electronics are suitable for fixed Installations in dry and humid rooms.
Technical data:
Operating peak voltage Uo/U | [V] | 225 | |
Test voltage at 50 Hz | core / core | [V]AC | 500 |
core / screen | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 10 |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | [Ohm/km] | 78,4 | |
max. | [nF/km] | 100 | |
Capacitance unbalance 100m | max. | [pF] | 200 |
Application:
Cables for industrial electronics are suitable for fixed Installations in dry and humid rooms.
Technical data:
Operating peak voltage Uo/U | [V] | 350 | |
Test voltage | [V]AC | 800 | |
Temperature range | in motion | +5°C till +50°C | |
Flammability | standard | EN 60332-1-2 | |
Conductor resistance | max. | [Ohm/km] | 26 |
Mutal capacitance | max. | [nF/km] | 130 |
Application:
To be installed in dry and humid rooms as termination and connection cable in the low-frequency and studio technology.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Insulation resistance | R iso | [MOhm/km] | 5000 |
Mutal capacitance | [Ohm/km] | 39 | |
Attenuation | 100 MHz | [dB / 100 m] | 4,5 |
Impedance | 1 KHz | [Ohm] | 465 |
Impedance | 10 KHz | [Ohm] | 155 |
Impedance | 100 KHz | [Ohm] | 115 |
Cross-talk attenuation | at 60 Hz | [dB/500 m] | 78 |
Application:
These transmission cables are to be installed in dry and humid rooms. They are used in data processing and process controlling for high-speed transmission.
Technical data:
Nominal voltage Uo/U | [V] | 125 volt | |
Temperature range | in motion | 0°C till +50°C | |
Conductor resistance | max. | [Ohm/km] | 110 |
Insulation resistance | min. | [GOhm/km] | 5 |
Mutal capacitance | nom. | [nF] max. | 29 |
Capacitance unbalance | max. | [nF] max. | 1 |
Bending radius | min. | v [mm] | 75 |
Application:
Suitable for applications indoors on the wall or in the floor as well as in cable ducts as a data transmission cable for IBM-LAN systems and EC-aprroved "non plenum type".
Technical data:
Operating peak voltage Uo/U | [V] | 300 | |
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Conductor resistance | max. | [Ohm/km] | 73,2 |
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | at 800 Hz | [nF] max. | 100 |
Test voltage | core / core | [KV] 5 min. | 1 |
Core and Screen on | |||
Conductorsurface | [KV] 1 min. | 4 | |
Bending radius | x diameter | 15 |
Application:
The installation in, on and under the wall surface, in dry, humid and wet locations as well as outdoors (if protected) is admissible. As BUS-installation cable (EIB-installation bus) it may be used in HV and LV installations, as control and instrumentation cable (MSR-cable) in HV installations. Suitable for the transmission of measuring data, for the installation in the processing and for the application in the field of the control technology.
Technical data:
Operating peak voltage Uo/U | [V] | 300 | |
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Conductor resistance | max. | [Ohm/km] | 130 |
Insulation resistance | min. | [GOhm/km] | 5 |
Impendance | 1-100 MHz | [Ohm]+-15% | 100 |
Mutal capacitance | nom. | [nF] max. | 52 |
Wave damping | 1,0 MHz | [dB/100 m] | 35 |
4,0 MHz | [dB/100 m] | 55 | |
10,0 MHz | [dB/100 m] | 73 | |
16,0 MHz | [dB/100 m] | 86 | |
Cross-talk attenuation | 1,0 MHz | [dB] | 30 |
10,0 MHz | [dB] | 30 |
Application:
This Integrated Services Digital Network (ISDN) cable is to be used as a termination and connection cable for the transmission of analogue to digital signals up to 16 MHz. It is suitable for ISDN applications in this frequency range such as BTX or fax. Peculiarities of this cable are the cores which are stranded to star quads.
Technical data:
Temperature range | in motion | -40°C till +70°C | |
Conductor resistance | max. | [Ohm/km] | 57,1 |
Insulation resistance | min. | [MOhm/km] | 1000 |
Impendance | 1,0-5,0 MHz | [Ohm] | 150 |
Bending radius | min. | [mm] | 150 |
For other types and standards please send us an inquiry. |
Application:
As an access and connection lines circuit in mechanical engineering, e.g., as a connection circuit between bus segments. By the special construction the circuit is suitable for the application with quick connection technology
Technical data:
Temperature range | in motion | -5°C till +60°C | |
one time / fixed | 0°C till +50°C | ||
Conductor resistance | max. | [Ohm/km] | 83 |
Impendance | 1-100 MHz | [Ohm]+-15% | 100 |
Mutal capacitance | nom. | [nF] max. | 50 |
Attenuation | 1,0 MHz | [dB/100 m] | 2,7 |
4,0 MHz | [dB/100 m] | 5,2 | |
10,0 MHz | [dB/100 m] | 8,4 | |
16,0 MHz | [dB/100 m] | 11,2 |
Application:
The circuit can connect different components within automation devices. The twisted cores are also the basic element. Because all bus components are connected about that, costly parallel wiring can be avoided.
Technical data:
Temperature range | in motion | 0°C till +50°C | |
Conductor resistance | max. | [Ohm/km] | 39 |
Attenuation | 1-100 MHz | [Ohm]+-15% | 150 |
Mutal capacitance | nom. | [nF] max. | 40 |
Application:
C(ontroller)A(rea)N(etwork) serves as a system circuit in the industrial range. Professional bus, CAN bus as well as devices LON can be connected with this system solution.
Technical data:
Temperature range | moved | 0°C till +60°C | |
Loop impedance | [Ohm/100 m] | 39 | |
Capacity | max. | [nF/km] | 50 |
Nom. Velocity of propagation | NVP nom. | 77 | |
Attenuation | 1-100 MHz | [Ohm] | 100,0 +/- 15 |
Capacity coupling (f=800 Hz) | K<100 | [pF/100 m] | 150 |
Insulation resistance | [GOhm/km] | 5 | |
Bending radius | under tension | 8,0 x Ø | |
no tension | 4,0 x Ø |
Application:
In the device connection wiring as a patch, switching, or connecting lead for the use in switching cabinets as well as for the connection of data terminals. Area of application: IEEE 802.3:10 Base T, 10 Base T Ethernet, 100 Base T, 1000 Base T, FDDI, ISDA, AT
Technical data:
Temperature range | moved | 0°C till +60°C | |
Loop impedance | [Ohm/100 m] | 19 | |
Capacity | max. | [nF/km] | 50 |
Nom. Velocity of propagation | NVP nom. | 77 | |
Attenuation | 1-100 MHz | [Ohm] | 100 |
Capacity coupling (f=800 Hz) | K<100 | [pF/100m] | 150 |
Insulation resistance | [GOhm/km] | 5 | |
Bending radius | under tension | 8,0 x Ø | |
no tension | 4,0 x Ø |
Application:
In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: IEEE 802.3:10 Base T, 10 Base T Ethernet, 100 Base T, 1000 Base T, FDDI, ISDA, ATM
Technical data:
Temperature range | moved | 0°C till +60°C | |
Loop impedance | [Ohm/100 m] | 19 | |
Capacity | max. | [nF/km] | 50 |
Nom. Velocity of propagation | NVP nom. | 71 | |
Attenuation | 1-100 MHz | [Ohm] | 100,0 +/- 15 |
Coupling resistance | 1-100 MHz | [mOhm/m] | 10 |
Capacity coupling (f=800 Hz) | K<100 | [pF/100 m] | 15 |
Insulation resistance | [GOhm/km] | >5 | |
Test voltage at 50 Hz | [VAC] | 1000 | |
Bending radius | under tension | 8,0 x Ø | |
no tension | 4,0 x Ø |
Application:
In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: IEEE 802.3:10 Base T, 10 Base T Ethernet, 100 Base T, 1000 Base T, FDDI, ISDA, ATM
Technical data:
Temperature range | moved | 0°C till +60°C | |
Loop impedance | [Ohm/100 m] | 19 | |
Capacity | max. | [nF/100m] | 50 |
Nom. Velocity of propagation | NVP nom. | 77 | |
Impendance | 1-100 MHz | [Ohm] | 100,0 +/- 15 |
Coupling resistance | 1-100 MHz | [mOhm/m] | 10 |
Capacity coupling (f=800 Hz) | K<100 | [pF/100 m] | 15 |
Insulation resistance | [GOhm/km] | >5 | |
Test voltage at 50 Hz | [VAC] | 700 | |
Bending radius | under tension | 8,0 x Ø | |
no tension | 4,0 x Ø |
Application:
In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: IEEE 802.3:10 Base T, 10 Base T Ethernet, 100 Base T, 1000 Base T, FDDI, ISDA, ATM
Technical data:
Temperature range | moved | 0°C till +60°C | |
Loop impedance | [Ohm/100 m] | 19 | |
Capacity | max. | [nF/km] | 50 |
Nom. Velocity of propagation | NVP nom. | 77 | |
Attenuation | 1-100 MHz | [Ohm] | 150,0 +/- 22 |
Coupling resistance | 1-100 MHz | [mOhm/m] | 10 |
Capacity coupling (f=800 Hz) | K<100 | [pF/100 m] | 150 |
Insulation resistance | [GOhm/m] | >5 | |
Test voltage at 50 Hz | [VAC] | 700 | |
Bending radius | under tension | 8,0 x Ø | |
no tension | 4,0 x Ø |
Application:
In the horizontal cabling as an installation for laying cable in cable channels and pipes inside of telecommunications equipment and data systems to 350 Mhz. Installation is very easy because of a central element (cross) no individual shield is required. Usable for: 10Base-T, 100 Base-T, 1000 Base-T, CDDI/TPDDI, ISDN, ATM 155 Mbit/s, TP-PMD 125 Mbit/s, Token Ring 4/16 Mbit/s.
Technical data:
Temperature range | moved | 0°C till +60°C | |
Loop impedance | [Ohm/100 m] | 14,5 | |
Capacity | max. | [nF/km] | 50 |
Nom. Velocity of propagation | NVP nom. | 77 | |
Attenuation | 1-100 MHz | [Ohm] | 100,0 +/- 25 |
Coupling resistance | 1-100 MHz | [mOhm/m] | <10 |
Capacity coupling (f=800 Hz) | K<100 | [pF/100 m] | 1500 |
Insulation resistance | [GOhm/m] | >5 | |
Test voltage at 50 Hz | [VAC] | 700 | |
Bending radius | under tension | 8,0 x Ø | |
no tension | 4,0 x Ø |
Application:
This installation cable is suitable for horizontal laying in cable ducts and conduits in telecommunications and data transmission systems. Useable for: ISDN , B-ISDN, IEEE 802.3 10 Base T Ethernet, IEEE 802.3 100 Base T Ethernet,IEEE 802.5 Token Ring, CDDI (FDDI on Cu), Gigabit-Ethernet , ATM, DQDB, Video.
Technical data:
Temperature range | moved | 0°C till +60°C | |
Loop impedance | [Ohm/100 m] | 14,5 | |
Capacity | max. | [nF/km] | 50 |
Nom. Velocity of propagation | NVP nom. | 77 | |
Attenuation | 1-100 MHz | [Ohm] | 100,0 +/- 25 |
Coupling resistance | 1-100 MHz | [mOhm/m] | 10 |
Capacity coupling (f=800 Hz) | K<100 | [pF/100 m] | 150 |
Insulation resistance | [GOhm/m] | >5 | |
Test voltage at 50 Hz | [VAC] | 700 | |
Bending radius | under tension | 8,0 x Ø | |
no tension | 4,0 x Ø |
Application:
In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: ISDA, B-ISDA, IEEE 802.3 10 Base T Ethernet, IEEE 802.3 100 Base T Ethernet, IEEE 802.5 Token Ring CCDI (FDDI at Cu), Gigabit-Ethernet, ATM, DQDB, Video
Technical data:
Temperature range | moved | -20°C till +60°C | |
Loop impedance | [Ohm/100 m] | 11,5 | |
Capacity | max. | [nF/km] | 50 |
Nom. Velocity of propagation | NVP nom. | 77 | |
Attenuation | 1-100 MHz | [Ohm] | 100,0 +/- 25 |
Coupling resistance | 1-100 MHz | [mOhm/m] | 10 |
Capacity coupling (f=800 Hz) | K<100 | [pF/100 m] | 150 |
Insulation resistance | [GOhm/m] | >5 | |
Test voltage at 50 Hz | [VAC] | 700 | |
Bending radius | under tension | 8,0 x Ø | |
no tension | 4,0 x Ø |
Application:
In the horizontal wiring as an installation cable for the transfer in cable canals as well as in pipes within telecommunication installations and data systems. Area of application: ISDA, B-ISDA, IEEE 802.3 10 Base T Ethernet, IEEE 802.3 100 Base T Ethernet, IEEE 802.5 Token Ring CCDI (FDDI at Cu), Gigabit-Ethernet, ATM, DQDB, Video
Technical data:
Temperature range | transport / storage | -30°C till +70°C | |
operational | -20°C till +60°C | ||
Bending radius | under tension | x diameter | 20 |
no tension | x diameter | 15 | |
Further types in singlemode or multimode style upon request |
Application:
This metal-free optical fibre outdoor cable is suitable for installations directly into the earth or in conduits in telecommunications and data processing systems. The stranded design (n x m) is available till 60 fibres, and with a multifunctional used reinforced glass roving braiding as a non-metallic stress relieving element and an armour for rodent protection.
Technical data:
Temperature range | transport / storage | -30°C till +70°C | |
operational | -20°C till +60°C | ||
Bending radius | under tension | x diameter | 20 |
no tension | x diameter | 15 | |
Further types in singlemode or multimode style upon request |
Application:
This metal-free optical fibre outdoor cable is suitable for installations directly into the earth or in conduits in telecommunications and data processing systems. The stranded design (n x m) is available till 60 fibres, and with a multifunctional used reinforced glass roving braiding as a non-metallic stress relieving element and an armour for rodent protection.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
fixed | -25°C till +60°C | ||
Flammability | standard | EN 60332-1-2 | |
Further cross-sections and core-quantities as well as standards and configurations upon request |
Application:
These cables are suitable for installations in dry, humid and wet locations as temperature measuring cables for areas such as the plastic industry in machine engineering, industrial oven construction as well as blast furnace plants in the steel industry. PVC-, fibre-glass- and asbestos-substitute insulated or sheathed compensating and extension cables are not suitable for open-air use except for the PVC-sheathed solid conductor type which can be used for underground laying, too.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
fixed | -25°C till +70°C | ||
Flammability | standard | EN 60332-1-2 | |
Further cross-sections and core-quantities as well as standards and configurations upon request |
Application:
These cables are suitable for installations in dry, humid and wet locations as temperature measuring cables for areas such as the plastic industry in machine engineering, industrial oven construction as well as blast furnace plants in the steel industry. PVC-, fibre-glass- and asbestos-substitute insulated or sheathed compensating and extension cables are not suitable for open-air use except for the PVC-sheathed solid conductor type which can be used for underground laying, too.
Technical data:
Temperature range | in motion | -25°C till +180°C | |
fixed | -25°C till +180°C | ||
temporary resilient | 250°C | ||
Flammability | standard | EN 60332-1-2 | |
Further cross-sections and core-quantities as well as standards and configurations upon request |
Application:
These cables are suitable for installations in dry, humid and wet locations as temperature measuring cables for areas such as the plastic industry in machine engineering, industrial oven construction as well as blast furnace plants in the steel industry. PVC-, fibre-glass- and asbestos-substitute insulated or sheathed compensating and extension cables are not suitable for open-air use except for the PVC-sheathed solid conductor type which can be used for underground laying, too.
Technical data:
Temperature range | in motion | -25°C till +180°C | |
fixed | -25°C till +180°C | ||
temporary resilient | 250°C | ||
Flammability | standard | EN 60332-1-2 | |
Further cross-sections and core-quantities as well as standards and configurations upon request |
Application:
These cables are suitable for installations in dry, humid and wet locations as temperature measuring cables for areas such as the plastic industry in machine engineering, industrial oven construction as well as blast furnace plants in the steel industry. PVC-, fibre-glass- and asbestos-substitute insulated or sheathed compensating and extension cables are not suitable for open-air use except for the PVC-sheathed solid conductor type which can be used for underground laying, too.