Rubber cables, crane-cables, lift-cables and building-cables

Technical data:

Nominal voltage Uo/U[V]300 / 500 volt
Test voltage[V]AC2000
Temperature rangein motion-25°C till +60°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter4
in motionx diameter8
FlammabilitystandardEN 60332-1-2

Application:

For general use in dry locations for connections of electrical apparatus submitted to weak mechanical strength, like vacuum cleaner, kitchen appliance, etc. unsuitable for industrial and agricultural use.

Technical data:

Nominal voltage Uo/U[V]450 / 750 volt
Test voltage[V]AC2500
Temperature rangein motion-25°C till +60°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter4
in motionx diameter8
Oil-resistantstandardEN 60811-2-1
FlammabilitystandardEN 60332-1-2

Application:

For general use in dry, humid and wet locations, for outdoor use, for agricultural applications or in locations subject to explosion hazards. Also suitable for connections of industrial and workshop electrical equipment submitted to medium-level mechanical stress. It can be used for fixed installations in temporary buildings as well as for connections of mobile machines and hoists.

Technical data:

Nominal voltage Uo/U[V]450 / 750 volt
Test voltage[V]AC2500
Temperature rangein motion-25°C till +60°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter4
in motionx diameter8
Oil-resistantstandardEN 60811-2-1
FlammabilitystandardEN 60332-1-2

Application:

For general use in dry, humid and wet locations, for outdoor use, for agricultural applications or in locations subject to explosion hazards. Also suitable for connections of industrial and workshop electrical equipment submitted to medium-level mechanical stress. It can be used for fixed installations in temporary buildings as well as for connections of mobile machines and hoists.

Technical data:

Nominal voltage Uo/U[V]600 / 1000 volt
Test voltage[V]AC4000
Temperature rangein motion-25°C till +80°C
Operating temperatureshort circuit°C250
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter4
in motionx diameter10
Oil-resistantstandardEN 60811-2-1
FlammabilitystandardEN 60332-1-2

Application:

These cables are suitable for extreme mechanical stress in dry and humid locations and outdoor use for connections of heavy equipment. For mines and industrial use.

Technical data:

Nominal voltage Uo/U[V]1000 volt
Temperature rangein motion-25°C till +80°C
FlammabilitystandardEN 60332-1-2

Application:

In dry and wet locations as well as outdoors for fixed installations. Suitable for span widths up to 20 m as a house lead-in cable, also for appliances within easy reach.

Technical data:

Nominal voltage Uo/U[V]1800 / 3000 volt
Test voltage[V]AC6000
Temperature rangein motion-25°C till +80°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter6
in motionx diameter10
Oil-resistantstandardEN 60811-2-1
FlammabilitystandardEN 60332-1-2

Application:

For track bound vehicles and trackless trolley buses as well as for installations in dry locations, in switchboards and distributors up to 1.000 V as a short circuit and earth fault proof cable at the nominal voltage of Uo / U 1.8 / 3 kV.

Technical data:

Nominal voltage Uo/U[V]100 / 100 volt
Test voltage[V]AC1000
Temperature rangein motion-20°C till +80°C
Operating temperatureshort circuit°C250
Short circuit timemax.[sec]5
Bending radiusmin.x diameter5
FlammabilitystandardEN 60332-1-2

Application:

For use on handheld electrodes keepers till 100 V with standardl flexibility.

Technical data:

Nominal voltage Uo/U[V]100 / 100 volt
Test voltage[V]AC1000
Temperature rangein motion-20°C till +80°C
Operating temperatureshort circuit°C250
Short circuit timemax.[sec]5
Bending radiusmin.x diameter5
FlammabilitystandardEN 60332-1-2

Application:

For use on handheld electrodes keepers till 100 V with high flexibility.

Technical data:

Nominal voltage Uo/U[V]300 / 500 volt
Test voltage[V]AC2000
Temperature rangein motion-25°C till +50°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusmin.x diameter6
FlammabilitystandardEN 60332-1-2

Application:

This cable is used in dry, humid and wet locations, as well as outdoors as a clamping cable for standardised lamp holders for the illumination of spaces and gardens.

Technical data:

Nominal voltage Uo/U[V]600 / 1000 volt
Test voltage[V]AC4000
Temperature rangein motion-20°C till +90°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusmin.x diameter8
Oil-resistantstandardEN 60811-2-1
FlammabilitystandardEN 60332-1-2

Application:

It is to be used in dry and humid locations as well as in the open-air for frequent reeling processes and when the cable is exposed to heavy tensile and torsion load as well as to forced bending as in the case of cable carriages, line chains, drums or other mechanical equipment. Travel speed up to 120 m/min.

Technical data:

Nominal voltage Uo/U[V]600 / 1000 volt
Test voltage[V]AC2500
Temperature rangein motion-35°Ctill +80°C
fixed-50°C till +80°C
Operating temperatureshort circuit°C250
Short circuit timemax.[sec]5
Bending radiusmin.x diameter8
Oil-resistantstandardEN 60811-2-1
FlammabilitystandardEN 60332-1-2

Application:

It is to be used as a connection cable for reeling purposes for very high mechanical loads on movable appliances, mobile line carriers, cable carriages as well as for vertical drum operation. It is also applicable for the scope of DIN VDE 0168 and 0118, for underground and open-cast mines.

Technical data:

Nominal voltage Uo/U[V]450 / 750 volt
Test voltage[V]AC2500
Temperature rangein motion-25°C till +60°C
Operating temperatureshort circuit°C250
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter4
Bending radiusin motionx diameter5
FlammabilitystandardEN 60332-1-2

Application:

To be used in dry, humid and wet locations as well as in the open-air as a flexible power and control cable for medium-level mechanical loads. This cable is suitable for connecting movable parts of machine tools, material handling equipment and large machines.

Technical data:

Nominal voltage Uo/U[V]300 / 500 volt
Test voltage[V]AC2000
Temperature rangein motion-25°C till +60°C
fixed-40°C till +80°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter3
Bending radiusin motionx diameter5
FlammabilitystandardEN 60332-1-2

Application:

It is to be used in dry, humid and wet locations as well as in the open-air as a flexible power and control cable for medium-level mechanical loads. This cable is suitable for connecting movable parts of machine tools, material handling equipment and large machines provided it is exposed to bending in only one plane.Cores grouped with individual groups sparated by a stay

Technical data:

Nominal voltage Uo/U[V]450 / 750 volt
Test voltage[V]AC2500
Temperature rangein motion-5°C till +70°C
Operating temperatureshort circuit°C160
Short circuit timemax.[sec]5
Bending radiusmin.x diameter10
FlammabilitystandardEN 60332-1-2

Application:

To be used in dry and humid locations but not in the open-air for low and medium-level mechanical loads. This cable is suitable for connecting movable parts of machine tools, material handling equipment and large machines provided it is exposed to bending in only one plane. Cables with more than 5 cores grouped with individual groups separated by a stay.

Technical data:

Nominal voltage Uo/U[V]450 / 750 volt
Test voltage[V]AC2500
Temperature rangein motion-35°C till +70°C
Operating temperatureshort circuit°C150
Short circuit timemax.[sec]5
Bending radiusmin.x diameter6
FlammabilitystandardEN 60332-1-2

Application:

This cable is suitable for connecting electrical equipment particularly on building sites. It is used in dry and damp locations, outdoors and in areas with explosion hazard.

Technical data:

Nominal voltage Uo/U[V]450 / 750 volt
Test voltage[V]AC2500
Temperature rangein motion-35°C till +70°C
Operating temperatureshort circuit°C160
Short circuit timemax.[sec]5
Bending radiusmin.x diameter6
FlammabilitystandardEN 60332-1-2

Application:

This cable is suitable for connecting electrical equipment particularly on building sites. It is used in dry and damp locations, outdoors and in areas with explosion hazard.

Technical data:

Nominal voltage Uo/U[V]300 / 500 volt
Test voltage[V]AC2000
Temperature rangein motion-40°C till +90°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter4
in motion x diameter5
Oil-resistantstandardEN 60811-2-1
FlammabilitystandardEN 60332-1-2

Application:

This termination and connection cable with high mechanical stress-resistance can be used in dry, damp or wet rooms as well as in the open-air. It is ideal for application in industrial plants, building sites, in fact everywhere where extreme wear and tear resistance is required and where the cable is subjected to hard utilisation.

Technical data:

Nominal voltage Uo/U[V]450 / 750 volt
Test voltage[V]AC2500
Temperature rangein motion-40°C till +90°C
Operating temperatureshort circuit°C200
Short circuit timemax.[sec]5
Bending radiusone time / fixedx diameter4
in motion x diameter5
Oil-resistantstandardEN 60811-2-1
FlammabilitystandardEN 60332-1-2

Application:

This termination and connection cable with high mechanical stress-resistance can be used in dry, damp or wet rooms as well as in the open-air. It is ideal for application in industrial plants, building sites, in fact everywhere where extreme wear and tear resistance is required and where the cable is subjected to hard utilisation.

This website uses cookies to provide services, personalize ads, and analyzing visitor. By using this site you agree. More informations