Rubber cables, crane-cables, lift-cables and building-cables
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -25°C till +60°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 4 |
in motion | x diameter | 8 | |
Flammability | standard | EN 60332-1-2 |
Application:
For general use in dry locations for connections of electrical apparatus submitted to weak mechanical strength, like vacuum cleaner, kitchen appliance, etc. unsuitable for industrial and agricultural use.
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -25°C till +60°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 4 |
in motion | x diameter | 8 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Application:
For general use in dry, humid and wet locations, for outdoor use, for agricultural applications or in locations subject to explosion hazards. Also suitable for connections of industrial and workshop electrical equipment submitted to medium-level mechanical stress. It can be used for fixed installations in temporary buildings as well as for connections of mobile machines and hoists.
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -25°C till +60°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 4 |
in motion | x diameter | 8 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Application:
For general use in dry, humid and wet locations, for outdoor use, for agricultural applications or in locations subject to explosion hazards. Also suitable for connections of industrial and workshop electrical equipment submitted to medium-level mechanical stress. It can be used for fixed installations in temporary buildings as well as for connections of mobile machines and hoists.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -25°C till +80°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 4 |
in motion | x diameter | 10 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Application:
These cables are suitable for extreme mechanical stress in dry and humid locations and outdoor use for connections of heavy equipment. For mines and industrial use.
Technical data:
Nominal voltage Uo/U | [V] | 1000 volt | |
Temperature range | in motion | -25°C till +80°C | |
Flammability | standard | EN 60332-1-2 |
Application:
In dry and wet locations as well as outdoors for fixed installations. Suitable for span widths up to 20 m as a house lead-in cable, also for appliances within easy reach.
Technical data:
Nominal voltage Uo/U | [V] | 1800 / 3000 volt | |
Test voltage | [V]AC | 6000 | |
Temperature range | in motion | -25°C till +80°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 6 |
in motion | x diameter | 10 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Application:
For track bound vehicles and trackless trolley buses as well as for installations in dry locations, in switchboards and distributors up to 1.000 V as a short circuit and earth fault proof cable at the nominal voltage of Uo / U 1.8 / 3 kV.
Technical data:
Nominal voltage Uo/U | [V] | 100 / 100 volt | |
Test voltage | [V]AC | 1000 | |
Temperature range | in motion | -20°C till +80°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 5 |
Flammability | standard | EN 60332-1-2 |
Application:
For use on handheld electrodes keepers till 100 V with standardl flexibility.
Technical data:
Nominal voltage Uo/U | [V] | 100 / 100 volt | |
Test voltage | [V]AC | 1000 | |
Temperature range | in motion | -20°C till +80°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 5 |
Flammability | standard | EN 60332-1-2 |
Application:
For use on handheld electrodes keepers till 100 V with high flexibility.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -25°C till +50°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 6 |
Flammability | standard | EN 60332-1-2 |
Application:
This cable is used in dry, humid and wet locations, as well as outdoors as a clamping cable for standardised lamp holders for the illumination of spaces and gardens.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -20°C till +90°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 8 |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Application:
It is to be used in dry and humid locations as well as in the open-air for frequent reeling processes and when the cable is exposed to heavy tensile and torsion load as well as to forced bending as in the case of cable carriages, line chains, drums or other mechanical equipment. Travel speed up to 120 m/min.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -35°Ctill +80°C | |
fixed | -50°C till +80°C | ||
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 8 |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Application:
It is to be used as a connection cable for reeling purposes for very high mechanical loads on movable appliances, mobile line carriers, cable carriages as well as for vertical drum operation. It is also applicable for the scope of DIN VDE 0168 and 0118, for underground and open-cast mines.
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -25°C till +60°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 4 |
Bending radius | in motion | x diameter | 5 |
Flammability | standard | EN 60332-1-2 |
Application:
To be used in dry, humid and wet locations as well as in the open-air as a flexible power and control cable for medium-level mechanical loads. This cable is suitable for connecting movable parts of machine tools, material handling equipment and large machines.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -25°C till +60°C | |
fixed | -40°C till +80°C | ||
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 3 |
Bending radius | in motion | x diameter | 5 |
Flammability | standard | EN 60332-1-2 |
Application:
It is to be used in dry, humid and wet locations as well as in the open-air as a flexible power and control cable for medium-level mechanical loads. This cable is suitable for connecting movable parts of machine tools, material handling equipment and large machines provided it is exposed to bending in only one plane.Cores grouped with individual groups sparated by a stay
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 160 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 10 |
Flammability | standard | EN 60332-1-2 |
Application:
To be used in dry and humid locations but not in the open-air for low and medium-level mechanical loads. This cable is suitable for connecting movable parts of machine tools, material handling equipment and large machines provided it is exposed to bending in only one plane. Cables with more than 5 cores grouped with individual groups separated by a stay.
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -35°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 6 |
Flammability | standard | EN 60332-1-2 |
Application:
This cable is suitable for connecting electrical equipment particularly on building sites. It is used in dry and damp locations, outdoors and in areas with explosion hazard.
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -35°C till +70°C | |
Operating temperature | short circuit | °C | 160 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 6 |
Flammability | standard | EN 60332-1-2 |
Application:
This cable is suitable for connecting electrical equipment particularly on building sites. It is used in dry and damp locations, outdoors and in areas with explosion hazard.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -40°C till +90°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 4 |
in motion | x diameter | 5 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Application:
This termination and connection cable with high mechanical stress-resistance can be used in dry, damp or wet rooms as well as in the open-air. It is ideal for application in industrial plants, building sites, in fact everywhere where extreme wear and tear resistance is required and where the cable is subjected to hard utilisation.
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -40°C till +90°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 4 |
in motion | x diameter | 5 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Application:
This termination and connection cable with high mechanical stress-resistance can be used in dry, damp or wet rooms as well as in the open-air. It is ideal for application in industrial plants, building sites, in fact everywhere where extreme wear and tear resistance is required and where the cable is subjected to hard utilisation.