Halogen-free cables and flame-resistant cables
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | +5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 6 |
Flammability | standard | EN 60332-1 | |
IEC 60332-1 |
Application:
For the internal wiring of switching systems, equipment and lights as well as for domestic installations, however, not for outdoor use.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | +5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 6 |
Flammability | standard | EN 60332-1 | |
IEC 60332-1 |
Application:
For fixed installations in devices and in or on lights, as well as for the house installation, especially for uses by their one low creation is demanded of smoke and corrosive gases in the fire case, however not outside.
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | one time / fixed | +5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 6 |
Flammability | standard | EN 60332-1 | |
IEC 60332-1 |
Application:
For the installation in electrical conduit on or under plaster or in similar closed systems especially for applications where there is a requirement for low smoke and corrosive gas creation in the event of fire, however not outside.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | +5°C till +70°C | |
Operating temperature | short circuit | °C | 160 |
Short circuit time | max. | [sec] | 5 |
Bending radius | in motion | x diameter | 12 |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C |
Application:
To be installed in buildings or industrial plants where many people and goods are concentrated. As they don't develop corrosive and halogen gases under the impact of fire, and the smoke and fume generation is also minimal, the damage caused is much smaller. They are destined for the installation on, in and under the wall-surface in dry, humid and wet locations as well as in brickwork or outdoors (when protected), but not directly into the earth.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -15°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | in motion | x diameter | 15 |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C |
Application:
For installations in dry, humid and wet locations, but not outdoors. These cables are used for fix or for flexible applications - but not with high tensile load or for forced bending.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | in motion | x diameter | 15 |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C |
Application:
For installations in dry, humid and wet locations but not outdoors. These cables are used for fix or for flexible applications - but not with high tensile load and for forced bending. Suitable as a signal and impulse cable in the control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | single-core style | x diameter | 15 |
multi-core style | x diameter | 12 | |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C |
Application:
Safety cables are used in all locations where a high degree of protection against fire and fire-damage has to be provided for human life and equipment and are, therefore, subject to high security requirements. These cables may be used indoors and outdoors. They may not be installed directly into the ground and into the water. This cable conforms to Safety Class II standards.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 12 |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C |
Application:
Safety cables are used in all locations where a high degree of protection against fire and fire-damage has to be provided for human life and equipment and are, therefore, subject to high security requirements. These cables may be used indoors and outdoors. They may not be installed directly into the ground and into the water. This cable conforms to Safety Class II standards.
Technical data:
Operating peak voltage | [V] | 300 volt | |
Temperature range | in motion | -5°C till +50°C | |
fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 7,5 |
Flammability | standard | EN 50266-2-4 | |
IEC 60332-3 Kat.C |
Application:
These installation cables are suitable for fixed installations in telecommunication and are to be used in locations with fire hazard to reduce damage in case of fire.
Technical data:
Operating peak voltage | [V] | 300 volt | |
Temperature range | in motion | -5°C till +50°C | |
fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 7,5 |
Flammability | standard | EN 50266-2-4 | |
IEC 60332-3 Kat.C |
Application:
Suitable for fixed installations in telecommunication and are to be used in locations with fire hazard to reduce damage in case of fire.
Technical data:
Operating peak voltage | [V] | 300 volt | |
Temperature range | in motion | -5°C till +50°C | |
Conductor resistance | max. | [Ohm/km] | 73,2 |
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | at 800 Hz | [nF] max. | 100 |
Test voltage | core / core | [KV] 5min. | 1 |
Core and Screen on conductorsurface | [KV] 1min. | 4 | |
Flammability | standard | EN 50266-2-4 | |
IEC 60332-1 |
Application:
For the installation on and under plaster in dry, humid and wet rooms as wellas outside (by protected installation) in Strongly and weak streamarrangements, as BUS cable as well as as a MSR cable in strong streamarrangements. The transference of measuring values, the application in theprocess data processing as well as the use in the area of the tax technologyand control technology are the main areas of application of this cable.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | single-core style | x diameter | 15 |
multi-core style | x diameter | 12 | |
Flammability | standard | EN 50266-2-4 | |
IEC 60332-3 Kat.C | |||
More types on enquiry |
Application:
Safety cables are used in all locations where a high degree of protectionagainst fire and fire-damage has to be provided for human life and equipmentand are, therefore, subject to high security requirements. These cables may beused indoors and outdoors. They may not be installed directly into the groundand into the water. This cable conforms with Safety Class II standards.Functional integrity of 30 minutes and insulation integrity of 180 minutes.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | in motion | x diameter | 12 |
Flammability | standard | EN 50266-2-4 | |
IEC 60332-3 Kat.C | |||
More types on enquiry |
Application:
Safety cables are used in all locations where a high degree of protectionagainst fire and fire-damage has to be provided for human life and equipmentand are, therefore, subject to high security requirements. These cables may beused indoors and outdoors. They may not be installed directly into the groundand into the water. Functional integrity of 30 minutes and insulation integrity of180 minutes.
Technical data:
Operating peak voltage | [V] | 225 volt | |
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 7,5 |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C | |||
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | [Ohm/km] | 73,2 | |
max. | [nF/km] | 120 | |
Capacitance unbalance 100m | max. | [pF] | 200 |
Application:
Suitable for fixed installations in telecommunication. They are to be used inlocations with fire hazard and where insulation integrity of at least 180 minutesand circuit integrity of at least 30 minutes are required.
Technical data:
Operating peak voltage | [V] | 225 volt | |
Temperature range | in motion | -5°C till +50°C | |
fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 7,5 |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C | |||
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | [Ohm/km] | 73,2 | |
max. | [nF/km] | 120 | |
Capacitance unbalance 100m | max. | [pF] | 200 |
Application:
Suitable for fixed installations in fire detection circuits. They are to be used inlocations with fire hazard and where an insulation integrity of at least 180minutes and a circuit integrity of at least 30 minutes are required.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | single-core style | x diameter | 15 |
multi-core style | x diameter | 12 | |
Flammability | standard | EN 50266-2-4 | |
IEC 60332-3 Kat.C | |||
More types on enquiry |
Application:
Safety cables are used in all locations where a high degree of protection against fire and fire-damage has to be provided for human life and equipment and are, therefore, subject to high security requirements. These cables may beused indoors and outdoors. They may not be installed directly into the groundand into the water. Functional integrity of 90 minutes and insulation integrity of 180 minutes.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | in motion | x diameter | 12 |
Flammability | standard | EN 50266-2-4 | |
IEC 60332-3 Kat.C | |||
More types on enquiry |
Application:
Safety cables are used in all locations where a high degree of protection against fire and fire-damage has to be provided for human life and equipment and are, therefore, subject to high security requirements. These cables may beused indoors and outdoors. They may not be installed directly into the ground and into the water. Functional integrity of 90 minutes and insulation integrity of 180 minutes.
Technical data:
Operating peak voltage | [V] | 225 volt | |
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 7,5 |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C | |||
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | [Ohm/km] | 73,2 | |
max. | [nF/km] | 120 | |
Capacitance unbalance 100m | max. | [pF] | 200 |
Application:
Suitable for fixed installations in telecommunication. They are to be used in locations with fire hazard and where insulation integrity of at least 180 minutes and circuit integrity of at least 90 minutes are required.
Technical data:
Operating peak voltage | [V] | 225 volt | |
Temperature range | in motion | -5°C till +50°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | in motion | x diameter | 7,5 |
Flammability | standard | EN 50266-2-4 | |
EN 60332-1 | |||
IEC 60332-3 Kat.C | |||
Insulation resistance | min. | [MOhm/km] | 100 |
Mutal capacitance | [Ohm/km] | 73,2 | |
max. | [nF/km] | 120 | |
Capacitance unbalance 100m | max. | [pF] | 200 |
Application:
Suitable for fixed installations in telecommunication. They are to be used in locations with fire hazard and where insulation integrity of at least 180 minutes and circuit integrity of at least 90 minutes are required.