PVC control cables, cables for frequency converter
Technical data:
Nominal voltage Uo/U | [V] | 300 / 300 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable in dry locations for connections in communication technology, mainly for HIFI applications such as a loudspeaker connecting cable.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 300 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable in dry locations for connections in communication technology, mainly for HIFI applications such as a loudspeaker connecting cable.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 300 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 6 |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable in dry locations for connections of portable electrical appliances submitted to weak mechanical strength, like radio sets and lighting fittings, but not for heating devices.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 300 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 6 |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable in dry locations for connections of portable electrical appliances submitted to weak mechanical strength, like radio sets and lighting fittings, but not for heating devices.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 300 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 6 |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable in dry locations for connections of portable electrical appliances submitted to weak mechanical strength, like radio sets and lighting fittings, but not for heating devices.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 5 |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable in dry and humid locations for connections of electrical appliances submitted to medium level mechanical strength, like washing machines, refrigerators, etc. Suitable for heating appliances provided that there is no risk of contact with hot parts.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 5 |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable in dry and humid locations for connections of electrical appliances submitted to medium level mechanical strength, like washing machines, refrigerators, etc. Suitable for heating appliances provided that there is no risk of contact with hot parts.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -5°C till +70°C | |
Bending radius | min. | x diameter | 8 |
Flammability | standard | EN 60332-1-2 |
Application:
With middle mechanical demands in dry, humid and wet locations, as well as for the installation outside, however not in earth.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -30°C till +90°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 6 |
in motion | x diameter | 15 | |
Flammability | standard | EN 60332-1-2 | |
More types on enquiry |
Application:
In dry and damp locations for low and medium-level mechanical stress, but not in the open-air. To be used as a termination and connection cable in the control, measuring and signal technology. Suitable as a signal and impulse cable for control and inspection of industrial plants, production lines and Machinery.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -30°C till +70°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 10 |
in motion | x diameter | 20 | |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable as a signal and impulse cable in the control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -40°C till +70°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 6 |
in motion | x diameter | 15 | |
Flammability | standard | EN 60332-1-2 |
Application:
Used as a power and control cable with increased mechanical stressresistance for rough operating conditions. This cable is also suitable for fixed installations in vehicles, machines and hoists, etc.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -40°C till +70°C | ||
Operating temperature | short circuit | °C | 150 |
Bending radius | one time / fixed | x diameter | 12,5 |
in motion | x diameter | 15 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 20 |
Application:
In dry and wet locations for low and medium-level mechanical stress, but not in the open-air. To be used as a termination and connection cable in the control, measuring and signal technology. Suitable as a signal and impulse cable for control and inspection of industrial plants, production lines and machinery.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage at 50 Hz | core / core | [V]AC | 2000 |
core / screen | [V]AC | 1000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -40°C till +70°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 12,5 |
in motion | x diameter | 15 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 20 |
Application:
Suitable for dry, damp and wet locations but not in the open-air. It is used as a screened termination and connection cable in the control, measuring and signal technology. Suitable as a signal and impulse cable for control and inspection of industrial plants, machinery and working processes.
Technical data:
Nominal voltage Uo/U | [V] | 600 volt | |
Test voltage | [V]AC | 3000 | |
Temperature range | in motion | -5°C till +90°C | |
one time / fixed | -40°C till +90°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 12,5 |
in motion | x diameter | 15 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 20 |
Application:
In dry and wet locations for low and medium-level mechanical stress, but not in the open-air. To be used as a termination and connection cable in the control, measuring and signal technology. Suitable as a signal and impulse cable for control and inspection of industrial plants, production lines and machinery.
Technical data:
Nominal voltage Uo/U | [V] | 600 volt | |
Test voltage | [V]AC | 3000 | |
Temperature range | in motion | -5°C till +90°C | |
one time / fixed | -40°C till +90°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 12,5 |
in motion | x diameter | 15 | |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 20 |
Application:
Suitable for dry, damp and wet locations but not in the open-air. It is used as a screened termination and connection cable in the control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies. Suitable as a signal and impulse cable for control and inspection of industrial plants, machinery and working processes.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -30°C till +70°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 6 |
in motion | x diameter | 15 | |
Flammability | standard | EN 60332-1-2 |
Application:
Suitable for dry, damp and wet locations as well as in areas with explosion hazard but not in the open-air. To be used as a connection and control cable for the application in intrinsically safe circuits for medium-level mechanical Stress.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -30°C till +70°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 10 |
in motion | x diameter | 20 | |
Flammability | standard | EN 60332-1-2 |
Application:
For dry, humid and wet locations as well as areas with explosion hazard, but not in the open-air. To be used as an MSR cable for the application in intrinsically safe circuits. The copper braiding optimises protection against external electrical and magnetic interferences. The cable is suitable for medium-level mechanical stress.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | one time / fixed | x diameter | 5 |
in motion | x diameter | 7,5 | |
Flammability | standard | EN 60332-1-2 |
Application:
These connection cables are well suited for fixed installations and for flexible use e.g. in machine and plant engineering for medium level mechanical stress in dry, damp and wet locations.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage at 50 Hz | core / core | [V]AC | 4000 |
core / screen | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -30°C till +70°C | ||
Bending radius | one time / fixed | x diameter | 7,5 |
in motion | x diameter | 15 | |
Flammability | standard | EN 60332-1-2 |
Application:
These connection cables are well suited for fixed installations and for flexible use e.g. in machine and plant engineering for medium-level mechanical stress in dry, damp and wet locations. With the copper braiding electrical and magnetic interferences exerted on other cables and wires or adjacent electric components are effectively suppressed. They are especially suitable as supply cables between frequency converters and servomotors.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage at 50 Hz | core / core | [V]AC | 4000 |
core / screen | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -30°C till +70°C | ||
Operating temperature | short circuit | °C | 160 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 7,5 |
in motion | x diameter | 15 | |
Flammability | standard | EN 60332-1-2 |
Application:
These composite connection cables are produced according to the European EMV Guidelines and are particularly suitable for plants and facilities with appliances and electrical equipment of which electromagnetic interference fields could have an undue influence on the surroundings. These connection cables are well suited for fixed installations and for flexible use in motive power engineering with frequency converting technology (e.g. machine and plant engineering) for medium-level mechanical loads in dry, humid and wet Locations.
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage at 50 Hz | core / core | [V]AC | 4000 |
core / screen | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -40°C till +70°C | ||
Operating temperature | short circuit | °C | 160 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 7,5 |
in motion | x diameter | 15 | |
Flammability | standard | EN 60332-1-2 |
Application:
These composite connection cables are produced according to the European EMV Guidelines and are particularly suitable for plants and facilities with appliances and electrical equipment of which electromagnetic interference fields could have an undue influence on the surroundings. These connection cables are well suited for fixed installations and for flexible use in motive power engineering with frequency converting technology (e.g. machine and plant engineering) for medium-level mechanical loads in dry, humid and wet locations and outdoor.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 3000 | |
Temperature range | in motion | -5°C till +70°C | |
one time / fixed | -40°C till +70°C | ||
Bending radius | one time / fixed | x diameter | 6 |
in motion | x diameter | 20 | |
Flammability | standard | EN 60332-1-2 |
Application:
Used as energy or connecting cable, as measuring, checking and control cable in machine tool manufacturing, plant engineering and on assembly lines and production lines to meet stringent safety requirements. Suitable for fixed installation or flexible applications with unrestricted mobility without forced movement control and without exposure to tensile load. Installation in dry and moist rooms.