Heat resistant cables
Technical data:
Nominal voltage Uo/U | [V] | 450 / 750 volt | |
Test voltage | [V]AC | 2500 | |
Temperature range | in motion | -25°C till +110°C | |
Operating temperature | short circuit | °C | 260 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 7 |
Flammability | standard | EN 60332-1-2 |
Application:
This wire is well suited for internal wiring in lamps, instruments, control panels and distributors in dry locations. It should be installed in surface mounted or embedded conduits.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -60°C till +180°C | |
temporary resilient | +250°C | ||
Flammability | standard | EN 60332-1-2 |
Application:
This wire is well suited for internal wiring in lamps, instruments, control panels and distributors for low mechanical stress particularly at high ambient Temperatures.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -60°C till +180°C | |
temporary resilient | +250°C | ||
Flammability | standard | EN 60332-1-2 |
Application:
This wire is well suited for internal wiring in lamps, instruments, control panels and distributors for low mechanical stress particularly at high ambient Temperatures.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -60°C till +180°C | |
temporary resilient | +250°C | ||
Flammability | standard | EN 60332-1-2 |
Application:
This wire is well suited for internal wiring in lamps, instruments, control panels and distributors. It is used for high mechanical stress, as the fibreglass braiding protects the silicone insulation from mechanical damages. It is halogen-free and heat resistant.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -60°C till +180°C | |
temporary resilient | +250°C | ||
Flammability | standard | EN 60332-1-2 |
Application:
In dry, humid and wet locations as well as in the open-air for low mechanical stress, particularly at high ambient temperatures.
DIN EN 60228 class 5 (construction)
HD 308 S2 (core identification) | |||
Technical data: | |||
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -60°C till +180°C | |
temporary resilient | +250°C | ||
Flammability | standard | EN 60332-1-2 |
Application:
In dry, humid and wet locations as well as in the open-air for low mechanical stress, particularly at high ambient temperatures. The armouring of galvanised steel wires protects the cable from mechanical damages.
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -60°C till +180°C | |
temporary resilient | +250°C | ||
Flammability | standard | EN 60332-1-2 |
Application:
In dry, humid and wet locations as well as in the open-air for low mechanical stress, particularly at high ambient temperatures. The copper braiding optimises protection against high-frequency external interference
Technical data:
Nominal voltage Uo/U | [V] | 16000 volt | |
Test voltage | [V]AC | 20000 | |
Temperature range | in motion | -60°C till +180°C | |
temporary resilient | +250°C | ||
Bending radius | min. | x diameter | 7,5 |
Flammability | standard | EN 60332-1-2 |
Application:
In automobiles and similar systems.