Coax cables
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Frequency range | F max. | [GHz] | 3 |
Insulation resistance | R iso | [MOhm/km] | 10000 |
Impendance | ZL | [Ohm] | 50 +/-2 |
Attenuation | 100 MHz | [dB / 100 m] | 15,3 |
Capacitance | C | [NF/km] | 100 |
Rel. velocity ratio | V rel | % | 67 |
Electric strength | 50 Hz | [KV] eff. | 5 |
Bending radius | min. | v [mm] | 25 |
Operating peak voltage | [kV] | 2,5 |
Application:
For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency signals and power.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Frequency range | F max. | [GHz] | 3 |
Insulation resistance | R iso | [MOhm/km] | 10000 |
Impendance | ZL | [Ohm] | 75 +/-3 |
Mutal capacitance | [Ohm/km] | 180 | |
Attenuation | 100 MHz | [dB / 100 m] | 11,1 |
Capacitance | C | [NF/km] | 67 |
Rel. velocity ratio | V rel | % | 67 |
Electric strength | 50 Hz | [KV] eff. | 7 |
Bending radius | min. | v [mm] | 30 |
Operating peak voltage | [kV] | 3,5 |
Application:
For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency signals and power.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Frequency range | F max. | [GHz] | 3 |
Insulation resistance | R iso | [MOhm/km] | 10000 |
Mutal capacitance | [Ohm/km] | 155 | |
Attenuation | 100 MHz | [dB / 100 m] | 9 |
Capacitance | C | [NF/km] | 45 |
Rel. velocity ratio | V rel | % | 83 |
Electric strength | 50 Hz | [KV] eff. | 3 |
Bending radius | min. | v [mm] | 30 |
Operating peak voltage | [kV] | 1,1 |
Application:
For indoor installation as well as in industrial areas in conduits and cableducts, for transmission of high frequency signals and power.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Frequency range | F max. | [GHz] | 3 |
Insulation resistance | R iso | [MOhm/km] | 10000 |
Impendance | ZL | [Ohm] | 50 +/-2 |
Attenuation | 100 MHz | [dB / 100 m] | 6,8 |
Capacitance | C | [NF/km] | 100 |
Rel. velocity ratio | V rel | % | 67 |
Electric strength | 50 Hz | [KV] eff. | 10 |
Bending radius | min. | v [mm] | 50 |
Operating peak voltage | [kV] | 5,2 |
Application:
For indoor installation as well as in industrial areas in conduits and cableducts, for transmission of high frequency signals and power.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Frequency range | F max. | [GHz] | 3 |
Insulation resistance | R iso | [MOhm/km] | 10000 |
Attenuation | 100 MHz | [dB / 100 m] | 7,7 |
Capacitance | C | [NF/km] | 67 |
Rel. velocity ratio | V rel | % | 67 |
Electric strength | 50 Hz | [KV] eff. | 10 |
Bending radius | min. | v [mm] | 50 |
Operating peak voltage | [kV] | 5,2 |
Application:
For indoor installation as well as in industrial areas in conduits and cableducts, for transmission of high frequency signals and power.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Frequency range | F max. | [GHz] | 3 |
Impendance | ZL | [Ohm] | 50 +/-2 |
Attenuation | 100 MHz | [dB / 100 m] | 6,7 |
Capacitance | C | [NF/km] | 100 |
Rel. velocity ratio | V rel | % | 66 |
Electric strength | 50 Hz | [KV] eff. | 2 |
Bending radius | min. | v [mm] | 50 |
Application:
For indoor installation as well as in industrial areas in conduits and cableducts, for transmission of high frequency signals and power.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Impendance | ZL | [Ohm] | 75 +/-3 |
Attenuation | 100 MHz | [dB / 100 m] | 8,4 |
300 MHz | [dB / 100 m] | 16 | |
450 MHz | [dB / 100 m] | 19,5 | |
850 MHz | [dB / 100 m] | 27,1 | |
DC resistance | inner conductor | [Ohm / km] | 47 |
outer conductor | [Ohm / km] | 23 | |
Bending radius | min. | v [mm] | 30 |
Shielding | [dB] | 75 |
Application:
Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Attenuation | 100 MHz | [dB / 100 m] | 8,2 |
300 MHz | [dB / 100 m] | 15,7 | |
450 MHz | [dB / 100 m] | 19 | |
850 MHz | [dB / 100 m] | 26,7 | |
DC resistance | inner conductor | [Ohm / km] | 43 |
outer conductor | [Ohm / km] | 19 | |
Bending radius | min. | v [mm] | 30 |
Application:
Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Impendance | ZL | [Ohm] | 75 +/-3 |
Attenuation | 100 MHz | [dB / 100 m] | 8,8 |
300 MHz | [dB / 100 m] | 15 | |
450 MHz | [dB / 100 m] | 17,5 | |
DC resistance | inner conductor | [Ohm / km] | 131 |
outer conductor | [Ohm / km] | 20 | |
Bending radius | min. | v [mm] | 30 |
Shielding | [dB] | 75 |
Application:
Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.
Technical data:
Impendance | ZL | [Ohm] | 75 +/-3 |
Attenuation | 100 MHz | [dB / 100 m] | 6,4 |
300 MHz | [dB / 100 m] | 11,1 | |
450 MHz | [dB / 100 m] | 13,8 | |
DC resistance | inner conductor | [Ohm / km] | 131 |
outer conductor | [Ohm / km] | 20 |
Application:
Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.
Technical data:
Temperature range | in motion | -5°C till +70°C | |
Impendance | ZL | [Ohm] | 75 +/-3 |
Attenuation | 100 MHz | [dB / 100 m] | 6,8 |
300 MHz | [dB / 100 m] | 11 | |
Capacitance | C | [NF / km] | 55 |
DC resistance | inner conductor | [Ohm / km] | 18 |
outer conductor | [Ohm / km] | 20 | |
Bending radius | min. | v [mm] | 45 |
Shielding | [dB] | 85 |
Application:
Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.