Coax cables

Technical data:

Temperature rangein motion-5°C till +70°C
Frequency rangeF max.[GHz]3
Insulation resistanceR iso[MOhm/km]10000
ImpendanceZL[Ohm]50 +/-2
Attenuation100 MHz[dB / 100 m]15,3
CapacitanceC[NF/km]100
Rel. velocity ratioV rel%67
Electric strength50 Hz[KV] eff.5
Bending radiusmin.v [mm]25
Operating peak voltage[kV]2,5

Application:

For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency signals and power.

Technical data:

Temperature rangein motion-5°C till +70°C
Frequency rangeF max.[GHz]3
Insulation resistanceR iso[MOhm/km]10000
ImpendanceZL[Ohm]75 +/-3
Mutal capacitance[Ohm/km]180
Attenuation100 MHz[dB / 100 m]11,1
CapacitanceC[NF/km]67
Rel. velocity ratioV rel%67
Electric strength50 Hz[KV] eff.7
Bending radiusmin.v [mm]30
Operating peak voltage[kV]3,5

Application:

For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency signals and power.

Technical data:

Temperature rangein motion-5°C till +70°C
Frequency rangeF max.[GHz]3
Insulation resistanceR iso[MOhm/km]10000
Mutal capacitance[Ohm/km]155
Attenuation100 MHz[dB / 100 m]9
CapacitanceC[NF/km]45
Rel. velocity ratioV rel%83
Electric strength50 Hz[KV] eff.3
Bending radiusmin.v [mm]30
Operating peak voltage[kV]1,1

Application:

For indoor installation as well as in industrial areas in conduits and cableducts, for transmission of high frequency signals and power.

Technical data:

Temperature rangein motion-5°C till +70°C
Frequency rangeF max.[GHz]3
Insulation resistanceR iso[MOhm/km]10000
ImpendanceZL[Ohm]50 +/-2
Attenuation100 MHz[dB / 100 m]6,8
CapacitanceC[NF/km]100
Rel. velocity ratioV rel%67
Electric strength50 Hz[KV] eff.10
Bending radiusmin.v [mm]50
Operating peak voltage[kV]5,2

Application:

For indoor installation as well as in industrial areas in conduits and cableducts, for transmission of high frequency signals and power.

Technical data:

Temperature rangein motion-5°C till +70°C
Frequency rangeF max.[GHz]3
Insulation resistanceR iso[MOhm/km]10000
Attenuation100 MHz[dB / 100 m]7,7
CapacitanceC[NF/km]67
Rel. velocity ratioV rel%67
Electric strength50 Hz[KV] eff.10
Bending radiusmin.v [mm]50
Operating peak voltage[kV]5,2

Application:

For indoor installation as well as in industrial areas in conduits and cableducts, for transmission of high frequency signals and power.

Technical data:

Temperature rangein motion-5°C till +70°C
Frequency rangeF max.[GHz]3
ImpendanceZL[Ohm]50 +/-2
Attenuation100 MHz[dB / 100 m]6,7
CapacitanceC[NF/km]100
Rel. velocity ratioV rel%66
Electric strength50 Hz[KV] eff.2
Bending radiusmin.v [mm]50

Application:

For indoor installation as well as in industrial areas in conduits and cableducts, for transmission of high frequency signals and power.

Technical data:

Temperature rangein motion-5°C till +70°C
ImpendanceZL[Ohm]75 +/-3
Attenuation100 MHz[dB / 100 m]8,4
300 MHz[dB / 100 m]16
450 MHz[dB / 100 m]19,5
850 MHz[dB / 100 m]27,1
DC resistanceinner conductor[Ohm / km]47
outer conductor[Ohm / km]23
Bending radiusmin.v [mm]30
Shielding[dB]75

Application:

Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.

Technical data:

Temperature rangein motion-5°C till +70°C
Attenuation100 MHz[dB / 100 m]8,2
300 MHz[dB / 100 m]15,7
450 MHz[dB / 100 m]19
850 MHz[dB / 100 m]26,7
DC resistanceinner conductor[Ohm / km]43
outer conductor[Ohm / km]19
Bending radiusmin.v [mm]30

Application:

Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.

Technical data:

Temperature rangein motion-5°C till +70°C
ImpendanceZL[Ohm]75 +/-3
Attenuation100 MHz[dB / 100 m]8,8
300 MHz[dB / 100 m]15
450 MHz[dB / 100 m]17,5
DC resistanceinner conductor[Ohm / km]131
outer conductor[Ohm / km]20
Bending radiusmin.v [mm]30
Shielding[dB]75

Application:

Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.

Technical data:

ImpendanceZL[Ohm]75 +/-3
Attenuation100 MHz[dB / 100 m]6,4
300 MHz[dB / 100 m]11,1
450 MHz[dB / 100 m]13,8
DC resistanceinner conductor[Ohm / km]131
outer conductor[Ohm / km]20

Application:

Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.

Technical data:

Temperature rangein motion-5°C till +70°C
ImpendanceZL[Ohm]75 +/-3
Attenuation100 MHz[dB / 100 m]6,8
300 MHz[dB / 100 m]11
CapacitanceC[NF / km]55
DC resistanceinner conductor[Ohm / km]18
outer conductor[Ohm / km]20
Bending radiusmin.v [mm]45
Shielding[dB]85

Application:

Suitable for applications in dry and humid locations as an aerial cable for community- and cable television networks. SAT-conform.

This website uses cookies to provide services, personalize ads, and analyzing visitor. By using this site you agree. More informations