LAN 600 (S/STP Pimf)

LAN 600 (S/STP Pimf)

Data Transmission Cable for Local Networks with Pair Wise Screening and Overall Shielding according to a Draft of Category 7

Application:

This installation cable is suitable for horizontal laying in cable ducts and conduits in telecommunications and data transmission systems. Useable for: ISDN , B-ISDN, IEEE 802.3 10 Base T Ethernet, IEEE 802.3 100 Base T Ethernet,IEEE 802.5 Token Ring, CDDI (FDDI on Cu), Gigabit-Ethernet , ATM, DQDB, Video.

Construction:

1 ..... solid bare copper, Ø 0,55 mm nebo 0,64 mm
2 ..... core insulation of foam-skin polyethylene
3 ..... pair wise shielding of plastic-laminated aluminium foil with a tinned drain wire Ø 0,4
4 ..... wide-meshed bare copper braiding
5 ..... outer sheath of polyvinylchloride (PVC) grey or halogen-free polymer compound, orange, special colours on enquiry

Standards:

EN 50288-4-1
IEC 332-1 , IEC 54-2, IEC 1034-2
IEC 708-1 (core identification)

Technical data:

Temperature rangemoved0°C till +60°C
Loop impedance[Ohm/100 m]14,5
Capacitymax.[nF/km]50
Nom. Velocity of propagationNVP nom.77
Attenuation1-100 MHz[Ohm]100,0 +/- 25
Coupling resistance1-100 MHz[mOhm/m]<10
Capacity coupling (f=800 Hz)K<100[pF/100 m]1500
Insulation resistance[GOhm/m]>5
Test voltage at 50 Hz[VAC]700
Bending radiusunder tension8,0 x Ø
no tension4,0 x Ø
Number of pairs and
nominal dimensions

AWG Nr.
Copper
figure

kg/km
Overall
diameter
appr.
mm
Calorific
potential

kWh/m
Tractive
force

N
Weight

appr.
kg/km
4 x 2 x AWG 23 PVC447,50,1719068
4 x 2 x AWG 23 FRNC447,50,1719068
2 x(4 x 2 x AWG 23) PVC8815,00,34380136
2 x(4 x 2 x AWG 23) FRNC8815,00,34380136