F-vYAY
F-vYAY
Installation Cable for Telecommunication
Application:
They are suitable for fixed installation indoors and are used for telecommunication purposes.
Construction:
1 ..... solid bare copper, Ø 0,5mm
2 ..... core insulation of polyvinylchloride (PVC)
3 ..... cores are stranded in concentric layers
4 ..... static screen of aluminium foil
5 ..... outer sheath of polyvinylchloride (PVC), grey
Standards:
according to ÖVE K35 - 1997 (core identification)
Technical data:
| Operating peak voltage | [V] | 200 V eff. / 300 V | |
| Test voltage at 50 Hz | core / core | [V]AC | 500 |
| core / screen | [V]AC | 2000 | |
| Temperature range | in motion | -5°C till +50°C | |
| one time / fixed | -30°C till +70°C | ||
| Bending radius | in motion | x diameter | 15 |
| Flammability | standard | EN 60332-1-2 | |
| Insulation resistance | min. | [MOhm/km] | 500 |
| Mutal capacitance | [Ohm/km] | 195,6 | |
| max. | [nF/km] | 100 | |
| Capacitance unbalance 100m | max. | [pF] | 500 |
| Number of pairs and nominal conductor diameter (mm) | Copper figure kg/km | Insulation thickness mm | Overall diameter appr. mm | Weight appr. kg/km | ||||
|---|---|---|---|---|---|---|---|---|
| 2 x 2 x 0,5 | 10 | 1,0 | 4,8 | 28 | ||||
| 3 x 2 x 0,5 | 14 | 1,0 | 5,2 | 33 | ||||
| 5 x 2 x 0,5 | 22 | 1,0 | 5,8 | 46 | ||||
| 6 x 2 x 0,5 | 25 | 1,0 | 6,3 | 53 | ||||
| 10 x 2 x 0,5 | 41 | 1,0 | 7,7 | 77 | ||||
| 15 x 2 x 0,5 | 61 | 1,0 | 9,0 | 107 | ||||
| 20 x 2 x 0,5 | 80 | 1,2 | 9,2 | 130 | ||||
| 30 x 2 x 0,5 | 120 | 1,2 | 10,7 | 185 | ||||
| 40 x 2 x 0,5 | 159 | 1,2 | 12,7 | 245 | ||||
| 50 x 2 x 0,5 | 198 | 1,4 | 14,3 | 300 | ||||
| 60 x 2 x 0,5 | 237 | 1,4 | 15,2 | 350 | ||||
| 100 x 2 x 0,5 | 396 | 1,6 | 19,5 | 555 | ||||

