F-2YJA2Y
F-2YJA2Y
Plastic Insulated Telecommunication Cable for Local Networks, transversely and longitudinally water-proof
Application:
They are suitable for the installation into the earth, in conduits, cable ducts and are used as network cables in industrial and operational plants, mainly in lowfrequency installations.
Construction:
1 ..... solid bare copper Ø 0,6/0,8 mm
2 ..... core insulation of polyethylene (PE)
3 ..... the interstices of the cable are filled with jelly, one layer of plasic foil
4 ..... screen of plastic laminated aluminium foil
5 ..... outer sheath of polyethylene (PE), black
Information:
conductor loop resistance:
core Ø 0,6 mm ..... < 130,0 Ohm/km
core Ø 0,8 mm ..... < 73,2 Ohm/km
Cores twisted to star-quads.
Core colours: transparent (or black by the start quad), red, green, blue
Standards:
adapted to austrian telecom standa
Technical data:
Operating peak voltage | [V] | 200 V eff. / 300 V | |
Test voltage at 50 Hz | core / core | [V]AC | 500 |
core / screen | [V]AC | 2000 | |
Temperature range | in motion | -20°C till +90°C | |
Bending radius | in motion | x diameter | 15 |
Insulation resistance | min. | [MOhm/km] | 5000 |
Mutal capacitance | max. | [nF/km] | 52 |
Capacitance unbalance 100m | max. | [pF] | 300 |
Number of pairs and nominal conductor diameter (mm) | Copper figure kg/km | Insulation thickness mm | Overall diameter appr. mm | Weight appr. kg/km | ||||
---|---|---|---|---|---|---|---|---|
6 x 2 x 0,6 | 36 | 1,8 | 11,0 | 125,0 | ||||
10 x 2 x 0,6 | 59 | 1,8 | 12,5 | 170,0 | ||||
20 x 2 x 0,6 | 115 | 1,8 | 16,5 | 310,0 | ||||
30 x 2 x 0,6 | 172 | 1,8 | 18,0 | 390,0 | ||||
50 x 2 x 0,6 | 285 | 1,8 | 22,0 | 580,0 | ||||
100 x 2 x 0,6 | 568 | 2,0 | 30,0 | 1.150,0 | ||||
6 x 2 x 0,8 | 62 | 1,8 | 12,5 | 170,0 | ||||
10 x 2 x 0,8 | 103 | 1,8 | 14,0 | 234,0 | ||||
20 x 2 x 0,8 | 203 | 1,8 | 19,5 | 450,0 | ||||
30 x 2 x 0,8 | 304 | 1,8 | 21,5 | 600,0 | ||||
50 x 2 x 0,8 | 504 | 2,0 | 26,5 | 920,0 | ||||
60 x 2 x 0,8 | 606 | 2,0 | 31,0 | 1.240,0 |