J-Y(ST)Y

J-Y(ST)Y

Installation Cable for Telecommunication

Application:

They are suitable for fixed installation indoors and are used for telecommunication purposes.

Construction:

1 ..... solid bare copper Ø 0,6/0,8 mm
2 ..... core insulation of polyvinylchloride (PVC)
3 ..... static screen of plastic laminated aluminium foil with drain wire
4 ..... outer sheath of polyvinylchloride (PVC), grey

Information:

conductor loop resistance:
core Ø 0,6 mm ..... <130,0 Ohm/km
core Ø 0,8 mm ..... < 73,2 Ohm/km

Standards:

DIN VDE 0815 (core identification)
DIN EN 60228 Class 1 (construction)
Flammability standard EN 60332-1-2 and 2-2

Technical data:

Operating peak voltage[V]300 V
Test voltage at 50 Hzcore / core[V]AC800
core / screen[V]AC800
Temperature rangein motion -5°C till +50°C
one time / fixed-30°C till +70°C
Bending radiusin motionx diameter15
Insulation resistancemin.[MOhm/km]100
max.[nF/km]10
Capacitance unbalance 100mmax.[pF]300
Number of pairs
and nominal
conductor diameter
(mm)
Copper
figure

kg/km
Insulation
thickness

mm
Overall
diameter
appr.
mm
Weight

appr.
kg/km
1 x 2 x 0,671,14,526
2 x 2 x 0,6131,14,935
3 x 2 x 0,6191,16,249
4 x 2 x 0,6241,16,658
5 x 2 x 0,6301,17,159
6 x 2 x 0,6361,17,661
10 x 2 x 0,6591,19,3113
12 x 2 x 0,6721,19,5129
20 x 2 x 0,61161,110,9191
30 x 2 x 0,61721,313,7284
40 x 2 x 0,62281,314,5358
50 x 2 x 0,62851,316,5438
60 x 2 x 0,63421,317,5512
100 x 2 x 0,65681,522,1829
1 x 2 x 0,8111,15,538
2 x 2 x 0,8211,16,154
3 x 2 x 0,8311,18,077
4 x 2 x 0,8411,18,794
5 x 2 x 0,8521,19,4114
6 x 2 x 0,8621,110,1135
10 x 2 x 0,81031,313,1205
12 x 2 x 0,81231,313,5235
16 x 2 x 0,81641,314,8299
20 x 2 x 0,82031,315,6352
30 x 2 x 0,83041,519,4522
40 x 2 x 0,84041,520,9663
50 x 2 x 0,85051,723,7832
60 x 2 x 0,86061,725,8978