F-2YA2Y

F-2YA2Y

Plastic Insulated Telecommunication Cable for Local Networks

Application:

They are suitable for the installation into the earth, in conduits, cable ducts and are used as network cables in industrial and operational plants, mainly in lowfrequency installations.

Construction:

1 ..... solid bare copper Ø 0,6/0,8 mm
2 ..... core insulation of polyethylene (PE)
3 ..... static screen of plastic laminated aluminium foil with drain wire Ø0,5 mm
4 ..... outer sheath of polyethylene (PE), black

Information:

conductor loop resistance:
core Ø 0,6 mm ..... 130,0 Ohm/km
core Ø 0,8 mm ..... 73,2 Ohm/km
Cores twisted to star-quads.
Core colours: transparent (or black by the start quad), red, green, blue

Standards:

adapted to austrian telecom standa

Technical data:

Operating peak voltage[V]200 V eff. / 300 V
Test voltage at 50 Hzcore / core[V]AC500
core / screen[V]AC2000
Temperature rangein motion-20°C till +90°C
Bending radiusin motionx diameter15
Insulation resistancemin.[MOhm/km]10000
Mutal capacitancemax.[nF/km]55
Capacitance unbalance 100mmax.[pF]1500
Number of pairs
and nominal
conductor diameter
(mm)
Copper
figure

kg/km
Insulation
thickness

mm
Overall
diameter
appr.
mm
Weight

appr.
kg/km
2 x 2 x 0,613,01,87,146,0
6 x 2 x 0,636,01,89,386,0
10 x 2 x 0,659,01,810,5120,0
20 x 2 x 0,6115,01,814,2210,0
30 x 2 x 0,6172,01,816,5280,0
40 x 2 x 0,6228,01,817,0355,0
50 x 2 x 0,6285,01,818,5425,0
60 x 2 x 0,6342,01,819,5485,0
100 x 2 x 0,6568,02,026,5820,0
2 x 2 x 0,822,01,87,665,0
6 x 2 x 0,862,01,810,4130,0
10 x 2 x 0,8103,01,812,2190,0
20 x 2 x 0,8203,01,816,4330,0
30 x 2 x 0,8304,01,818,2460,0
40 x 2 x 0,8404,01,819,8580,0
50 x 2 x 0,8504,02,021,6700,0
60 x 2 x 0,8606,02,023,1780,0
100 x 2 x 0,81.008,02,031,31.350,0
This website uses cookies to provide services, personalize ads, and analyzing visitor. By using this site you agree. More informations