H03VVH2-F (YML-fl)
H03VVH2-F (YML-fl)
PVC Sheathed Wire Flat
Application:
Suitable in dry locations for connections of portable electrical appliances submitted to weak mechanical strength, like radio sets and lighting fittings, but not for heating devices.
Construction:
1 ..... fine-stranded bare copper
2 ..... polyvinylchloride (PVC) insulation
3 ..... polyvinylchloride (PVC) outer sheath
Standards:
DIN VDE 0281-5
HD 21.5 S3 +A1+A2
DIN EN 60228 class 5 (construction)
HD 308 S2 (core identification)
Technical data:
Nominal voltage Uo/U | [V] | 300 / 300 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 6 |
Flammability | standard | EN 60332-1-2 |
Number of cores and nominal cross section mm2 | Colours | Copper figure kg/km | Cond. construction (appr. value) mm | Overall measures appr. mm | Weight appr. kg/km | ||
---|---|---|---|---|---|---|---|
2 x 0,75 | sw | 15 | 24 x 0,21 | 4,4/5,6 | 33 | ||
2 x 0,75 | gr/ws/br | 15 | 24 x 0,21 | 4,4/5,6 | 33 |