A03VV-F
A03VV-F
PVC Sheathed Wire
Application:
Suitable in dry locations for connections of portable electrical appliances submitted to weak mechanical strength, like radio sets and lighting fittings, but not for heating devices.
Construction:
1 ..... fine-stranded bare copper
2 ..... polyvinylchloride (PVC) insulation
3 ..... polyvinylchloride (PVC) outer sheath
Standards:
DIN VDE 0281-5
HD 21.5 S3 +A1+A2
DIN EN 60228 class 5 (construction)
HD 308 S2 (core identification)
ÖVE / Östandard E8241 (HD21)
Technical data:
Nominal voltage Uo/U | [V] | 300 / 300 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 6 |
Flammability | standard | EN 60332-1-2 |
Number of cores and nominal cross section mm2 | Colours | Copper figure kg/km | Cond. construction (appr. value) mm | Overall diameter appr. mm | Weight appr. kg/km | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
5 G 0,5 | hgr | 25,0 | 16 x 0,21 | 7,2 | 72 | |||||||
5 G 0,75 | hgr | 37,5 | 24 x 0,21 | 7,7 | 82 | |||||||
ws/sw | 37,5 | 24 x 0,21 | 7,7 | 82 | ||||||||
2 X 1 | hgr | 20,0 | 30 x 0,21 | 5,8 | 55 | |||||||
br/ws | 20,0 | 30 x 0,21 | 5,8 | 55 | ||||||||
3 G 1 | hgr/ws | 30,0 | 30 x 0,21 | 6,2 | 60 | |||||||
br/sw | 30,0 | 30 x 0,21 | 6,2 | 60 | ||||||||
4 G 1 | hgr | 40,0 | 30 x 0,21 | 6,8 | 72 | |||||||
ws | 40,0 | 30 x 0,21 | 6,8 | 72 |